  • AC outlets Qty.: 42 AC outlet(s)

APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

G-forbes APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black
Quick Code: Q773442Part Code: AP8853
Quick Code: Q773442Part Code: AP8853APC
Quick Code: Q773442
In Stock

Order now to avoid disappointment
Same day despatch when ordered
before 4pm Mon - Fri
Consumers may return unwanted items within 14 days of delivery.
Faulty items can be returned within 30 days of delivery.

Returns can be processed online or you can contact our customer service team. For more information see our returns section
RRP £1572.00 SAVE 51%
£643.45 ex. VAT
£772.14



Wishlist addFavourite

Overview



APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.




Specification


Technical Description: APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
Type:Characteristics of the device.
Single-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered

Features
Certification:
RoHS, REACH IEC 60950,VDE
Cable length:How long the cable is.
3 m

General
Type:Characteristics of the device.
Power Distribution Units (PDUs)

Management features
Monitoring:
Current, Power, Voltage

Operational conditions
Operating relative humidity (H-H):
5 - 95%
Storage relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
5 - 45 °C

Ports & interfaces
Output connections:
36x IEC 320 C13 6x IEC 320 C19
Input connection type:The type of connection /port for the input(s) into this device e.g. USB.
IEC 309 32A 2P+E
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
42 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
7680 W
Maximum total current draw per phase:
32 A
Maximum input current per phase:
32 A
Load capacity:
7680 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
AC input frequency:
50 - 60 Hz

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
6.93 kg
Dimensions (WxDxH):Dimensions of the product (Width x Depth x Height).
56 x 44 x 1791 mm


Delivery Options

5 Working Days FREE
3 Working Days £4.95
Next Working Day £7.95
More delivery info

Product details


AP8853 APC 0731304277019 B0009PTHF0

APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

£772.14 and In stock

SKUAP8853

Email me for later Close Email me for later Open
Email me a link to this page for later
Note: Your email address will not be used for any other purpose
Continue
Cookies help us deliver the best experience on our website. By using our website, you agree to our use of cookies

This site uses cookies. Some of these cookies are essential, while others help us to improve your experience by providing insights into how the site is being used. Read more about our privacy policy.

Some necessary cookies enable core functionality. The website cannot function properly without these cookies, and can only be disabled by changing your browser preferences.
Analytical and Functional cookies
Analytical cookies for us to better craft the user experience based on your page view experiences.
Social and Chat Cookies
We use some social sharing plugins. These plugins may place cookies on your device.