APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

G-forbes 1U, 16A, 208/230V, 50/60 Hz, 8x IEC 320 C13, IEC-320 C20, 445 x 108 x 44 mm, 2270 g

Quick Code: Q45793Part Code: AP7921BAPC
Videos & images may be added by customers.
Please check the specifications
APC AP7921B
 
Product Image
 
Product Image
 
Product Image
 

APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

G-forbes 1U, 16A, 208/230V, 50/60 Hz, 8x IEC 320 C13, IEC-320 C20, 445 x 108 x 44 mm, 2270 g
Quick Code: Q45793Part Code: AP7921B
  • AC outlets Qty.: 8 AC outlet(s)

APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black

G-forbes 1U, 16A, 208/230V, 50/60 Hz, 8x IEC 320 C13, IEC-320 C20, 445 x 108 x 44 mm, 2270 g
Quick Code: Q45793Part Code: AP7921B
Quick Code: Q45793Part Code: AP7921BAPC
Quick Code: Q45793
In Stock

Order now to avoid disappointment
Same day despatch when ordered
before 4pm Mon - Fri
Consumers may return unwanted items within 14 days of delivery.
Faulty items can be returned within 30 days of delivery.

Returns can be processed online or you can contact our customer service team. For more information see our returns section
RRP £1800.00 SAVE 54%
£691.90 ex. VAT
£830.28



Wishlist addFavourite

Overview



Availability

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Network Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Marketing

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Agility

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.




Specification


Technical Description: 1U, 16A, 208/230V, 50/60 Hz, 8x IEC 320 C13, IEC-320 C20, 445 x 108 x 44 mm, 2270 g

Design
Product colour:
Black
Mounting:
Horizontal/Vertical
Rack capacity:The spase that device fill in rack.
0U/1U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered, Switched

Features
Certification:
cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI, REACH
Cable length:How long the cable is.
2.5 m

Management features
Outlet control:
Lock-out, Recycle, Turn off, Turn on
Monitoring:
Current, Power, Voltage

Operational conditions
Non-operating altitude:
1 - 15000 m
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
0 - 95%
Storage relative humidity (H-H):
0 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 45 °C

Packaging content
Packaging content:
Installation Guide, Rack Mounting Brackets, User Manual

Packaging data
Package dimensions (WxDxH):Dimensions of the packaged product (Width x Depth x Height).
470 x 343 x 70 mm
Package weight:Weight of the packaged product.
3.45 kg

Ports & interfaces
Input connection type:The type of connection /port for the input(s) into this device e.g. USB.
IEC-320 C20
AC outlet types:The type of outlet for AC electricity.
C13 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
C20 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
8 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
3680 W
Maximum total current draw per phase:
16 A
Maximum input current per phase:
16 A
Load capacity:
3680 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
208-230 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
16 A
AC input frequency:
50 - 60 Hz
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
200-230 V

Technical details
Sustainability certificates:
RoHS

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
2.27 kg
Dimensions (WxDxH):Dimensions of the product (Width x Depth x Height).
445 x 108 x 44 mm


Delivery Options

5 Working Days FREE
3 Working Days £4.95
Next Working Day £7.95
More delivery info

Product details


AP7921B APC 0731304331629 B01N000J77

1U, 16A, 208/230V, 50/60 Hz, 8x IEC 320 C13, IEC-320 C20, 445 x 108 x 44 mm, 2270 g

£830.28 and In stock

SKUAP7921B

Email me for later Close Email me for later Open
Email me a link to this page for later
Note: Your email address will not be used for any other purpose
Continue
Cookies help us deliver the best experience on our website. By using our website, you agree to our use of cookies

This site uses cookies. Some of these cookies are essential, while others help us to improve your experience by providing insights into how the site is being used. Read more about our privacy policy.

Some necessary cookies enable core functionality. The website cannot function properly without these cookies, and can only be disabled by changing your browser preferences.
Analytical and Functional cookies
Analytical cookies for us to better craft the user experience based on your page view experiences.
Social and Chat Cookies
We use some social sharing plugins. These plugins may place cookies on your device.